Model NO.: XJ-300
Trademark: Newtopp
Specification: XJ-300
Origin: China
Model NO.: XJ-300
Trademark: Newtopp
Specification: XJ-300
Origin: China
Application field:

Used to twisted wire and parallel wire single layers/double layers continuous centering tapping. 



Machine  technical parameter:
  1. Wire specification:AWG32-AWG42(0.2-0.5mm)
  2. Aluminum foil tape,cotton paper tape,transparent tape,mica tape,teflon tape etc.
  3. Rotate speed:Max2000rpm/Max18m/min
  4. Power:Speed regulation by 1HP servomotor plus servo controller,wrapping plate is linkage with capstan motor
  5. Wrapping tension:Wrapping tension automatic calculation tracking and keep constant from start to end.Needn't any artificial adjustment.
  6. Heating device:Auto flexible type with Omron temperature control,the temperature will controlled within ±1ºC
  7. Take-up tension:Take-up tension keep constant from start to end,needn't any adjustment.
  8. Take-up: Axis-row type take up, no damage during the traversing process,distance can be set freely according the wire specification
  9. Pay-off type:Straight line slide rail slider heavy hammer tension type power pay-off with variable frequency speedf regulation and set the break line protection function.

Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping



Machine parts:
 
No. Parts name&Specs. Qty
1 ø200-300mm four-heads dynamic pay-off  1set
2 ø300mm centering tapping device 2set
3 Electrical control cabinet(touch screen) 1set
4 Automatic heating machine 1set
5 Ø300mm Axis row-type take up machine 1set

Main parts brand

1.Motor: Siemens
2.Frequency converter: Yaskawa
3.Bearing: NSK  (Japan brand) 
4.Electrical component: Siemens or Omron
5.PLC controller: Siemens
6.Touch screen: Tontek (Taiwan) 





Our Service

Pre-Sales Service                                      After-Sales Service

* Inquiry and consulting support.              * Training how to install the machine,  and how to use the machine. 
* Customized design support.                   * Engineers available to service machinery overseas.
* View our Factory.



About us

Company introduction


Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Dongguan NewTopp Electrical Machinery Co.,Ltd is a high-tech enterprise which professional in design and manufacture high-end wire and cable equipment,manily have the whole factory production line solution of Civil construction/power wire&cable,whole factory production line solution of Lan cable cat8/5E/6/6A/7,whole factory production line solution of HDMI,USB,SATA,RG59,6 etc. High frequency wire and cable,equipment include the copper bunching machine,teflon extrusion machine,insulation extrusion machine, chemical foaming extrusion machine,physical foaming extrusion machine,jacket sheath extrusion machine,planetary type cage twisting/stranding machine, numerical control type double layers/multi layers taping machine,cantilever type single twisting/stranding machine,Lan cable back-twist pair twisting/stranding machine etc. For more information please log in our official website http://www.en.newtopp.com or feel free to contact us directly.


Our products

Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Products in client site
Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Certification and Patent
Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping


 Contact us

Contact person: Owen Zeng
Mob :+86-17390410655





DongGuan Newtopp Electrical Machinery Co.,Ltd.
http://www.en.newtopp.com  
Tel.:+86-769-85372062   Fax:+86-769-85340833
Add.:No.286, Huaide Road, Humen Town,Dongguan City, Guangdong Province.




  Application field:

Used to twisted wire and parallel wire single layers/double layers continuous centering tapping. 



Machine  technical parameter:
  1. Wire specification:AWG32-AWG42(0.2-0.5mm)
  2. Aluminum foil tape,cotton paper tape,transparent tape,mica tape,teflon tape etc.
  3. Rotate speed:Max2000rpm/Max18m/min
  4. Power:Speed regulation by 1HP servomotor plus servo controller,wrapping plate is linkage with capstan motor
  5. Wrapping tension:Wrapping tension automatic calculation tracking and keep constant from start to end.Needn't any artificial adjustment.
  6. Heating device:Auto flexible type with Omron temperature control,the temperature will controlled within ±1ºC
  7. Take-up tension:Take-up tension keep constant from start to end,needn't any adjustment.
  8. Take-up: Axis-row type take up, no damage during the traversing process,distance can be set freely according the wire specification
  9. Pay-off type:Straight line slide rail slider heavy hammer tension type power pay-off with variable frequency speedf regulation and set the break line protection function.

Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping



Machine parts:
 
No. Parts name&Specs. Qty
1 ø200-300mm four-heads dynamic pay-off  1set
2 ø300mm centering tapping device 2set
3 Electrical control cabinet(touch screen) 1set
4 Automatic heating machine 1set
5 Ø300mm Axis row-type take up machine 1set

Main parts brand

1.Motor: Siemens
2.Frequency converter: Yaskawa
3.Bearing: NSK  (Japan brand) 
4.Electrical component: Siemens or Omron
5.PLC controller: Siemens
6.Touch screen: Tontek (Taiwan) 





Our Service

Pre-Sales Service                                      After-Sales Service

* Inquiry and consulting support.              * Training how to install the machine,  and how to use the machine. 
* Customized design support.                   * Engineers available to service machinery overseas.
* View our Factory.



About us

Company introduction


Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Dongguan NewTopp Electrical Machinery Co.,Ltd is a high-tech enterprise which professional in design and manufacture high-end wire and cable equipment,manily have the whole factory production line solution of Civil construction/power wire&cable,whole factory production line solution of Lan cable cat8/5E/6/6A/7,whole factory production line solution of HDMI,USB,SATA,RG59,6 etc. High frequency wire and cable,equipment include the copper bunching machine,teflon extrusion machine,insulation extrusion machine, chemical foaming extrusion machine,physical foaming extrusion machine,jacket sheath extrusion machine,planetary type cage twisting/stranding machine, numerical control type double layers/multi layers taping machine,cantilever type single twisting/stranding machine,Lan cable back-twist pair twisting/stranding machine etc. For more information please log in our official website http://www.en.newtopp.com or feel free to contact us directly.


Our products

Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Products in client site
Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping

Certification and Patent
Xj300 Micro Coaxial Wire Taping Machine/Parallel Wire Double Layers Wrapping


 Contact us

Contact person: Owen Zeng
Mob :+86-17390410655





DongGuan Newtopp Electrical Machinery Co.,Ltd.
http://www.en.newtopp.com  
Tel.:+86-769-85372062   Fax:+86-769-85340833
Add.:No.286, Huaide Road, Humen Town,Dongguan City, Guangdong Province.




 

The insulation breakdown accident often occurred in generator. It includes interphases short circuit, inter-turn short circuit and ground fault.

    The interphase short circuit: the generator windings ends will be greatly impacted by electric power and may make the coil end deformed under two-phase or three-phase short circuit and differential protection tripping happening.

   Inter-turn short circuit: Generator outlet blasting, if it continues a long time, the stator copper wire will be melted. When no-load run, the generator three-phase voltage will be imbalance.

   Ground fault: Generator breakdown location is in the linear portion or notch position and stator ground protection act. The insulation resistance value between stator ground and ground is zero or minimum.

   The fundamental reason of generator insulation breakdown is that the stator coil insulation is weak or there is a corona etching in notch in run time. The treatment method is to find the point of breakdown and reworked and reinforced insulation. At the same time, eliminating the corona etching in a maximum extent is important.

III. A large noise or vibration with generator

   The reasons of a large noise or vibration with generator are:

   1. Foundation bolts loose, or STG subsidence. Treatment: fastening bolts. Recalibration concentricity.


   2. Generator rotor and Steam Turbine shaft are misalignment. Treatment: calibration concentricity.


   3. Bearing wall worn or damaged under short oil. Treatment: repaired bearing or replace a new bearing with same model.


   4. There is a friction between the stator and rotor. Treatment: find the friction location and reason, and then eliminate it.


   5. Fan or other fasteners loose. Treatment: Tighten fan and fasteners.


   6. Rotor coil partial short circuit, two points grounding or wiring errors. Treatment: please inspect the insulation of slip ring and the rotor coil to the ground. Or connect to the DC power source and check the voltage drop of each coil, winding direction and wiring method. So we can identify the cause of the malfunction and eliminate them.


  7. Brush is too hard, or the pressure is too large. Treatment: adjust the pressure or replace the same type of brush.


  8. Three-phase current are severe asymmetry. Treatment: please investigate that the three-phase current imbalance is in the allowable range or not. If it is not in the allowable range, please adjust three-phase load or reduce the load.


   9. Stator winding short circuit or ground. Treatment: Find out the fault and repair it.


   10. External fault or lightning strike. Treatment: if the vibration time is too long, please stop the STG and inspect.


Typical

cases:


   This is a 15 MW generator from a Shandong customer. The vibration of generator is reached to 0.12mm in running. After inspection the generator, we found that rotor dynamic AC impedance upheaval 12% in 2400-2700 and the dynamic inter-turn short circuit is serious. It destroys the balance of the magnetic field and causes the electromagnetic force uneven of generator rotor. After removal of the rotor retaining ring and treatment the rotor inter-turns, we start the STG. The vibration is about 0.01mm.


IV. The temperature of a generator is too high.


   Generally the temperature of a generator will be in the allowable value, if the generator running normally and the current, voltage, frequency, power, excitation current and power factor are all within the allowable fluctuation range. If a generator stator, core and other parts temperature are too high, please consider the following cases:


   1. Generator overload operation and exceed the allowable time. Treatment: Please reduce the generator load to the rated load or under rated load as soon as possible.


   2. Three-phase current are serious imbalance. Treatment: please find out the reason of imbalance. If it is the voltage causing, please check if it is the generator inter-turn short circuit. If it is load causing, please adjust the load and make it balance.


   3. The ventilation cooling system of generator is poor. For example, the temperature is too high, the air duct or exhaust duct are blocked, the coil and its ends are serious fouling. Treatment: please reduce the load suitability, improve ventilation, and remove fouling.


   4. The stator winding portion short circuit or ground. Treatment: Find out the short circuit or ground point and repair them, and then eliminate short circuit or ground risks.


   5. Insulation of the stator core may be partially damaged and short circuit, so there is a vortex and overheat. Treatment: please reduce the load suitability. If the generator reduces its efficiency obviously, please repair the generator stator core.


   6. The bearing is short of lubricating oil. The oil number is wrong. The oil quality is bad. The bearing is installed with a wrong way or the bearing is damaged. Treatment: please find out the reason and then replace the oil or clean, adjust or replace bearing.



V. Generator rotor ground


   Symptom: Generator grounding one point or two points grounding light plate light.


   Fault Analysis: Generator rotor winding insulation damage, coil deformity and severe dust and greasy attached in the ends seriously are all leading to the grounding of the generator rotor windings. When the generator rotor winding grounding in one point, there is electrical current pass as the ground does not constitute an electrical circuit.

However, after one point grounded, it is easy of leading another grounding point. If any part in excitation circuit ground, it can form ground fault of two or more points ground. It is very dangerous.

After the failure, the rotor windings are short-circuited. Because of the small winding DC resistance, the excitation current will increase. So the magnetic field of generator is out of balance, and main magnetic flux reduces largely. So the STG will vibrant strongly. Meanwhile the power factor of the generator will be increased significantly and get into leading phase running (absorption of reactive power from the grid).


   The stator field becomes in the frond and the rotor field becomes in the back. It will make the stator current increases. If the watcher notice that there is no excitation varying but the excitation current and stator current suddenly increases, and the excitation voltage and AC voltage are all suddenly drop, and power factor meter indicates increasing or leading phase, it means the generator rotor grounded or inter-turn short circuited. You should shut down the STG and blow-out magnetic. Please inspect the excitation system and rotor windings, and find out the short circuit point and treat it.  



VI. Excitation upgrading and generator test


   Excitation system upgrading, brushless exciter changes into the SCR excitation and make the generator maintenance easily. And it removes the disadvantage of brushless excitation dynamic adjustment slowly. The generator test includes stator insulation resistance test, the absorption ratio test, the iron loss test, leak test, AC and DC voltage withstand test, the rotor high speed balancing and overspeed test, dynamic and static AC impedance test, the generator no-load test, short circuit test, temperature rise test, residual pressure measurement, axis voltage measurement.



Generator Care

Generator Care,Steam Turbine Generator Care,Msw Power Generation,Combined Cycle Generating Unit

Shandong Qingneng Power Co., Ltd. , https://www.steamturbine.be